Gib Bracing Guide - Gib Braceline on one face. The most modern machinery and trained labor enable us to do construction for you that are reliable strong and beautiful.


Gib Co Nz

Encourages more even bracing distribution throughout the building.

Gib bracing guide. For specification and installation advice for Ecoply used in typical applications refer to the following sections. Our diverse product range includes plasterboard steel framing systems decorative acoustic and air cleaning wall ceiling linings facade linings and plaster finishing compounds and accessories for internal applications. GIB Site Guide 2018 - General Wall and Ceiling Installation Section.

Length 900 to 2400mm Gib Braceineð on one face min length 06m. Fastener Centres Fasten 50 100 and 150mm from each corner and 150mm thereafter around the perimeter of the bracing element. GIB SITE GUIDE SEPTEMBER 2018 GIB.

Typical Application Section Structural bracing and ceiling diaphragms 30 Roofs and decks 40 Flooring 50 Note. When a new wider door is added on bracing line B replacement bracing could be added. Updated GIB EzyBrace Bracing Design Software - improved user interface with simplified bracing design process.

Nails or GIB Bracelinescrews at 100mm centres using the GIB Braceline corner fixing pattern. Fix using 35mm x 6g. Bracing 2b bracing 2a bracing 1b Scenarios.

GIB Site Guide 2018 - Joint and Finishing Section. For horizontal fixing place single. Key benefits of the GS2-NOM bracing element include.

Developed in conjunction with MiTek the GIB HandiBrac has been designed and tested for use as a hold-down bracket in GIB BL and UP bracing elements. Update to openings in bracing elements and ceilings diaphragms. Detailed in the current GIB Site Guide.

GIB Site Guide 2018 - Repairs and Maintenance Section. Requirements of the current GIB Site Guide to contribute bracing resistance. Clause 834 and Tables 81 to 85.

GIB Site Guide 2018 - Pre Installation Section. GS2-NOM is a new bracing element added to GIB Bracing Systems. Refer below for Product Data and Installation.

GIB Standard GIB Fyreline GIB Aqualine GIB Ultraline GIB Toughline With the wide range of plasterboard types there are some overlaps in functionality. For vertical fixing place fasteners at 300mm centres at intermediate sheet joints. Siniats range of plasterboard products for residential and commercial internal wall and ceiling linings includes standard 10mm and 13mm board and performance boards for fire water impact and sound resistance together with specialty multi-function board.

P21 A wall bracing test and evaluation procedure This outlines the P21 test method for wall bracing elements which is called up in NZS 36042011 Timber-framed buildings as the means to determine wind and earthquake ratings of timber-framed sheet-lined bracing elements for buildings. GS2-NOM allows internal walls to be lined with GIB plasterboard on both sides and fastened off as per the standard fixing requirements of the current GIB Site Guide to contribute to bracing resistance. When an internal wall is removed on bracing line O replacement bracing could be added on a parallel bracing line less than 2 m.

Length 1200 to 2400mrn Gib Braceline and Gib Board on opp. To use standard GIB Site Guide GS2-NOM fixing on bracing plans. 51 Bracing Systems GIB 59 511 Installation Summary 60 512 System Specifications 61 513 Bottom Plate Fixing 63 514 Panel Hold-Down Details 63 515 GIB EzyBrace Corner Fastener Pattern 65 516 Permitted GIB EzyBrace.

On both sides of the door 1a to the internal wall also on bracing line B 1b. NEW GIB Bracing Element GS2-NOM. USG Boral Bracing System UB1FR 13mm Fiberock Aqua-Tough on one side 14 - 15 USG Boral Bracing System UB2FR 13mm Fiberock Aqua-Tough on both sides 16 - 17 USG Boral Bracing System UBFRP 13mm Fiberock Aqua-Tough on one side 7mm DD Structural Plywood on the other side 18 - 19.

GIB sheets may be installed vertically or horizontally with sheet edges touching joints stopped and reinforced in accordance with the GIB Site Guide. More information available at wwwgibconz. GIB EzyBrace Systems were updated in September 2016.

Failure to follow GIB Bracing System specifications could result in the bracing panel not achieving the required bracing resistance. Bracing Design Process Clause 831 1. Determine the wind pressure Clause 832 Tables 81 to 85 3.

Clause 833 and Figure 82A or B 4. Fastening the GIB Plasterboard Fasteners 32mm x 6g GIB Grabber Screws or 35mm GIB Nails. GS2-NOM - DESIGN APPROACH 1 The design example in Figure 2 below shows designated bracing elements GS1-N and BL1-H used around the perimeter of the house.

1Potentially reduces the amount of fasteners. Calculate the racking force. Actual savings dependent on building and bracing design.

Design the bracing systems. GIB EzyBrace Systems 2016 are a range of wall and ceiling bracing systems based on the use of GIB Standard GIB Braceline and other GIB plasterboards. Length 1200 to 2400mm Gib Braceline on one face 75mm ply on other.

A note is added that all remaining GIB plasterboard linings are fixed at the nominal GIB Site Guide pattern. Technical notes referenced in this guide can be downloaded from wwwchhwoodproductsconz or. GIB Site Guide 2018 - Performance Systems Section.

Bracing elements to resist wind are placed in line with the ridge and wind direction see Figure 2. Lastly since we are a company that highly values quality in our work we take special care in using machinery to achieve our purposes and complementing it with skilled labor. GIB SITE GUIDE DECEMBER 2014 For further information visit gibconz or phone 0800 100 442 3 GIB WARRANTY STATEMENT WE ARE 100 BEHIND OUR PRODUCTS AND SYSTEMS If any of our products or systems fail to perform as claimed or an issue associated with any GIB product or system does occur Winstone Wallboards will work with the relevant.

Siniat Australia is a part of Etex leaders in lightweight construction materials. Length 900 to 2400m Gib Braceline on one face 475mm hardboard on other. GIB Site Guide 2018 - Product Range Section.

New GIB Bracing element - GS2- NOM. To calculate the required bracing units along the building multiply W by the value in the right-hand Along column in NZS 36042011 Table 55 subfloor 56 upper or. Determine the wind classification Clauses 142 15 AS4055ASNZS11702 2.

GIB Aqualine can be used in place of GIB Bracelinein GIB bracing elements 900mm or longer provided the perimeter of the element is fixed with GIB Braceline. Length 900 to 1200mm Gib Braceline on one face. Determine the area of elevation.

Bracing function can be met but noise control will be reduced. A tick indicates that the board can perform the same function as that of the original board. GIB EzyBrace Systems 2016 are used to resist earthquake and wind loads on timber-framed buildings designed and constructed in accordance with NZS 3604 and the GIBFix Framing System.

GIB HandiBrac now with BOWMAC Screw Bolts. Winstone Wallboards is New Zealands only manufacturer and largest marketer of gypsum plasterboard and manufactures under the GIB Brand.


Gib Bracing Systems Pdf Framing Construction Roof


Gib Bracing Pdf Document


Nzwoodproducts Co Nz


Gib Co Nz


09 13 Pdf Gib Fasteners Brochure Manualzz


Gib Co Nz


Gib Co Nz


Gs1 N Gib


Jameshardie Co Nz


Gib Co Nz


Professional Building Consultants Calculating Bracing When Renovating


Gib Co Nz


Nzwoodproducts Co Nz


Jameshardie Co Nz


Related Posts